Coriolis mass flow meter manufacturer today: In terms of cost, electromagnetic flow meters are more affordable than mass flow meters. The cost of electromagnetic flow meters is moderate. It is suitable for more users. Mass flow meters have higher measurement accuracy, but they are also more expensive. For customers with specific needs. What is mass flow meter? Measures Mass Flow: A mass flow meter measures the mass passing through a pipe or conduit in a specified amount of time. The unit of measurement is typically kilograms per second (kg/s) or another mass-related unit. Discover even more info on coriolis flow meter manufacturers.
Comprehensively consider the use requirements and procurement costs of gas turbine flowmeters. When the customized gas turbine flow meter did not appear in the domestic brand, the international brand can be said to be a super profitable product. A medium-sized gas turbine flow requires hundreds of thousands or even hundreds of thousands of yuan. And our domestic brands struggle tenaciously in a harsh environment where the strength and weakness are not an order of magnitude at all. It can be seen that when selecting a gas turbine flow meter, there are many factors to be considered, not only from before the purchase, but also after the purchase of the gas turbine flowmeter, all of which need to be considered. When choosing a gas turbine flowmeter, you must be careful!
To calculate the steam mass flow from the frequency signal output by the frequency output vortex flowmeter, you only need to know the current working condition of the fluid, while the temperature and pressure compensation of the analog output vortex flowmeter is only the error caused by the deviation of the current working condition from the design working condition. Compensation, therefore, not only need to know the current conditions, but also need to know the design conditions. The data of the latter working condition often causes errors due to the loss of data due to the passage of time or personnel changes. In contrast, the frequency output vortex flowmeter does not have this problem.
Day for day vast quantities of oil and gas are transported across the globe, refined and transported further. Mature and foolproof technology is essential. But it is the control through instrumentation and visualisation that help make all these processes safe and reliable. The Coriolis Insertion Density Meters could be used for the detection of the liquid’s density. The insertion density meters are the best choices for the proccess control as the basic parameters of density, and also for the quality control with the solid percentage or the concentration for references.
Ultrasonic flow meters enable users to perform flow measurement inspections at many points in the flow process without the need for permanent installation. This universal driving time timer has a dual-function button interface, an ergonomic handheld design, and a beautiful backlit color digital display that greatly simplifies setup and data collection. Compared with other traditional flowmeters or high temperature ultrasonic flow meter, it has the characteristics of high accuracy, high reliability, high performance, and low cost. The flowmeter also has other advantages: TVT technology design. Fewer hardware components, low-voltage broadband pulse transmission, and low power consumption. Clear, user-friendly menu selections make the flowmeter easy to use. Daily, monthly and yearly total traffic. The parallel operation of positive, negative, and net flow is displayed cumulatively by a scale factor (span) and a 7-digit number. See even more information at https://www.bjssae.com/.
Beijing Sincerity has developed over years to manufacture the Coriolis Mass Flow Meters industries. Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and – no less importantly – in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.
Install the total steam flow meter before the pressure reducing valve. Since the above-mentioned steam has not been decompressed, there is no phase change problem, so install the flowmeter before the pressure reducing valve, and use the saturated steam compensation method to ensure the measurement Accuracy. If the flowmeter can only be installed behind the pressure reducing valve, a pressure transmitter can be added for temperature and pressure compensation. If the stability of the pressure reducing valve is good, the upstream pressure value of the flowmeter can be set as a constant value in the display instrument for temperature and pressure compensation.